Oct 6, 2013 · Sta-Rite Sr400Hd Max-E-Therm Error Codes Ad0, Sf1, 888, 180, R4. Pool Heater; Sta-Rite; Ad0; Sf1; 888; 180; r4; SR400HD 29. Mar 10, 2012. #2. UPDATE: Sta Rite Max-E-Therm 400 LP problems, help please! I am no longer suspecting the problem is the control board on the heater unit. The heater and spa pumps, lights, etc. are controlled by a Hayward Goldline Pro Logic PL-P-8 with the main and two remote control pads. The heater would not come on with …Aug 15, 2013 · I have recently been having issues with my Starite Max-E-Therm heater (model no. SR400NA). I have been trying to follow the trouble-shooting steps in the installation/owners manual, to no avail. The Symptom: Turn the heater on Pool "or" Spa, and bump the temperature setting to a few degrees above the standing temperature I have Sta-Rite 200 Max-E-Therm Pool Heater - 200K Btu - Hello , I have Sta-Rite 200 Max-E-Therm Pool Heater - 200K Btu - Natural Gas Heater will not ignite. I can smell gas.I have a 3 year old Sta-Rite heater (Max-E-Therm 400 BTU Natural Gas Heater). When I turn it on, the blower activates but the gas is not igniting; the front panel lights up the "Service Heater" item. When I turn the top over and look at the circuit board, it has LED 4 and LED 11 shining bright red. I would like to troubleshoot and fix this ... guest a miidixielandsoftware Max-E-Therm® High Performance ASME® Certified Heaters. Ultra-High ASME® certified performance in a compact, quiet and eco-friendly design for your commercial application. New bronze header design allows for easy access to the thermal regulator and bypass valve service without use of special tools. Upgrades to thermal regulator include a ...Save money and energy with the Max-E-Therm High-Performance Heater. Already known as being dependable and efficient, Max-E-Therm now offers smart features and an optional energy-saving automatic bypass to help you ensure your pool is ready whenever you are. Smart connectivity via the Pentair IntelliCenter® Control System enables management of ...I have a 3 year old Sta-Rite heater (Max-E-Therm 400 BTU Natural Gas Heater). When I turn it on, the blower activates but the gas is not igniting; the front panel lights up the "Service Heater" item. When I turn the top over and look at the circuit board, it has LED 4 and LED 11 shining bright red. I would like to troubleshoot and fix this ...PentairApr 23, 2019 · This repair will solve most of the service light issues and heater automatically shutdown. I recommend replacing the manifold with the kit listed below. Th... V e rify that gas supply is open all the w a y to Gas V alv e , and Gas V alv e is set at ÒonÓ position. Chec k for 24 V A C to Gas V alv e ter minals dur ing ignition try.(V oltage …Heater was working fine then just stopped. Initial call to tech support and found transformer dead. Replaced- still blowing fuse. Tech call #2- told control board was bad, replaced it- still blowing fuse. Tech call #3- again, after about an hour, was told to replace membrane switch. Replaced it, fuse still blows right when I throw the circuit ... karamja elite osrskrogdalo horse gear crafting Mar 26, 2019. #9. A 400,000 BTU heater will heat a 22,000 gallon pool around 2 degrees an hour. Check that the heat exchanger is not rusted and starting to have pinholes that leak water as the heater runs.Nov 8, 2021 · Hi Nicole. Generally, the Pentair heater stops heating due to one or more reasons like Bad or damaged temperature sensors, the incorrect temperature setting of the thermostat, and bad internal bypass, blocked filter or pump basket, ignition malfunctions from the pilot lit, undersized pool heater, or severe defects on the heater elements. $14.99 $43.60 Free Shipping Hassle Free Return Quantity: Add to cart Description A stack flue sensor, located on the exhaust elbow of a pool heater, prevents the flue gas output from exceeding 500°F. When this fails, your system will show error codes E05 or E06 to indicate that the stack flue sensor must be replaced. This control board kit is designed to use with Pentair MasterTemp NA and LP Series pool and spa heater electrical systems. Also fits Pentair Sta-Rite Max-E-Therm NA and LP Series pool and spa heater electrical systems. Measures 6-inch length by 6-inch height by 6-inch width. Do not attempt to adjust the gas input by adjusting the regulator setting. roundy's supermarkets distribution warehouse Equipment includes: Hayward Pro Grid D.E. Filter (not sure exact model, will have to take another look), Pentair WF-26 Motor, Pentair MasterTemp 400, and a Pentair IntelliChlor IC40. Reply Report gasbuddy blairsville gahero wars anniversary event View and Download STA-RITE Max-E-Therm® operation & installation manual online. 120/240 VAC NATURAL GAS/LP GAS Pool & Spa Heater. Max-E-Therm® swimming pool heater pdf manual download. Also for: Max-e-therm sr200na, Max-e-therm sr200lp, Max-e-therm sr200hd, Max-e-therm sr333na,... Installation must be in accordance with all local codes and/or the latest edition of the National Fuel Gas Code, Z233.1 and the National Electrical Code, ANSI/NFPA70 (U.S.), or standards CSA B149 – INSTALLATION CODESMax-e-therm Sr400na controlled by an Aqualogic. I set the temperature of my spa to heat, say to the max of 104 degrees. The heater turns on and runs well until the water temp reads 94-95 degrees. The heater stops heating as if it reached the desired temperature. Its always the same temperature when it stops heating. rouses sulphur la #1 Tonight my heater was cycling on and off with error code of 128 r=5 code showing, any ideas? I seem to remember the last couple time this happened it was I …Nov 8, 2018 · PENTAIR MASTERTEMP 400 ERROR LIGHT LED EXPLAINED PVT-PILOT 1.47K subscribers Subscribe 83K views 4 years ago WHAT DO THE ERROR LIGHTS/LEDS MEAN ON THE BACK OF THE CONTROL BOARD? IDENTIFY... rockland county obituaries journal news STA-RITE Max-E-Therm SR400NA Owner's Manual (38 pages) SR POOL AND SPA HEATER 120/240 VAC NATURAL GAS/LP GAS 200K BTU/HR; 333K BTU/HR; 400K BTU/HR. Brand: STA-RITE | Category: Swimming Pool Heater | Size: 1.92 MB. Table of Contents. Posted May 31, 2013. I've got a Sta-Rite Max-E-Therm 400 and it won't start. When I power it up, the display shows 888 with the "Pool On" light green, then the "Pool On" light goes off and and the display changes to 128, then the display reads r=8, then E06 and the "Service Heater" lights up red. On the back of the panel, all the LEDs flash ...- Auto (360p LQ) Laptop Troubleshooting and Repair Guide STA-RITE Max-E-Therm 400 Troubleshooting While the heater is not working at 90 percent, there is nothing wrong with the heater. Few reasons can term to the machine not working as, Someone got the pump basket clogged up Filter pressure got way too high The filters need to be back washedI have Sta-Rite 200 Max-E-Therm Pool Heater - 200K Btu - Hello , I have Sta-Rite 200 Max-E-Therm Pool Heater - 200K Btu - Natural Gas Heater will not ignite. I can smell gas.Home | Dominion Energy harry potter protected by death fanfiction When the Jandy system commands it on, the display briefly lights up but then turns off. Any ideas are greatly appreciated. It has been working nearly flawlessly, minus the two flue temperature sensors I have had to replace, for nearly two years since I …Mar 28, 2020. #1. I have a Pentair Mastertemp 400 with an AFS light on. The heater turns on and runs for 10 seconds and turns off and throws the light on. Before this light came on I replaced the pressure switch, high limit switch, thermistor, manifold bypass valve, and control board due to an issue caused by the bypass valve in the …Questions Your Pool Heater Just Got a Whole Lot Smarter Save money and energy with the Max-E-Therm High-Performance Heater. Already known as being dependable and …STA-RITE Max-E-Therm SR400NA Owner's Manual (38 pages) SR POOL AND SPA HEATER 120/240 VAC NATURAL GAS/LP GAS 200K BTU/HR; 333K BTU/HR; 400K BTU/HR. Brand: STA-RITE | Category: Swimming Pool Heater | Size: 1.92 MB. Table of Contents. This repair will solve most of the service light issues and heater automatically shutdown. I recommend replacing the manifold with the kit listed below. Th...Jun 20, 2014 · By way of background, I had a technician come out but I think he missed the AFS light because he never mentioned it to me, instead showing me that he doesn't get a reading when he uses a voltmeter on the female connector from the board that connects to the male ignition switch lead. I have a problem that I am hoping someone can help me with. I have a 3 year old Sta-Rite heater (Max-E-Therm 400 BTU Natural Gas Heater). When I turn it on, the blower activates but the gas is not igniting; the front panel lights up the "Service Heater" item. When I turn the top over and look at the circuit board, it has LED 4 and LED 11 ...The temperature displayed is the water temperature. The SFS checks the exhaust gas temperature. To check the stack flue temperature, press and hold the "Pool On" button for about 5 to 10 seconds. If you remove the two halves of the heater cover, you can access the sfs. It's in the 90 of the exhaust flue. allen isd portalinsipid crossword clue 5 letters Oct 6, 2013 · Sta-Rite Sr400Hd Max-E-Therm Error Codes Ad0, Sf1, 888, 180, R4. Pool Heater; Sta-Rite; Ad0; Sf1; 888; 180; r4; SR400HD Hi Nicole. Generally, the Pentair heater stops heating due to one or more reasons like Bad or damaged temperature sensors, the incorrect temperature setting of the thermostat, and bad internal bypass, blocked filter or pump basket, ignition malfunctions from the pilot lit, undersized pool heater, or severe defects on the heater elements.Mar 6, 2019 · I replaced the Thermistor thinking that was the issue ( old thermistor had some pitting and corrosion) Immediately after I replaced it, the unit clicked and threw an E 01 code on the membrane read out. It would then not startup, or show anything except the E01. I checked all connections.... good. Home Improvement Questions Pool And Spa Repair Hello, Thank you for the description. The "R2D2" is the Sta-Rite Max-e-Therm. It is either a 200k or 400k heater, but they are essentially the same. Sounds like your problem is the Temperature sensor or "Thermistor".This item Pentair/Sta-Rite Ignition Control, MasterTemp/Max-E-Therm #42001-0052S Pentair 472447 Digital Module Ignition Control Replacement MiniMax Pool and Spa Heater Zodiac R0491300 Ignition Controlwe have a Sta Rite Max-E-Therm 400. The heater comes on, runs for a minute and turns off. Red service heater light comes on. after 30seconds heater ignites again runs for a minute or so. turns off again. on the back of the control panel the diode for HLS comes on i replaced the sensor, the thermistor and the thermal regulator. next i …Installation must be in accordance with all local codes and/or the latest edition of the National Fuel Gas Code, Z233.1 and the National Electrical Code, ANSI/NFPA70 (U.S.), or standards CSA B149 – INSTALLATION CODESFirst, locate the heater circuit breaker. Turn the breaker “Off” and leave the breaker for some while in this position. Then, turn on the breaker. Now, open the digital control mode of your heater. Select the “Mode” settings. Go to the “Standby” setting. Press the “Up” and “Down” buttons simultaneously.STA-RITE Max-E-Therm SR400HD Owner's Manual (38 pages) SR POOL AND SPA HEATER 120/240 VAC NATURAL GAS/LP GAS 200K BTU/HR; 333K BTU/HR; 400K BTU/HR. Brand: STA-RITE | Category: Swimming Pool Heater | … apartments for rent in san jose ca craigslist STA-RITE Max-E-Therm SR400NA Owner's Manual (38 pages) SR POOL AND SPA HEATER 120/240 VAC NATURAL GAS/LP GAS 200K BTU/HR; 333K BTU/HR; 400K BTU/HR. Brand: STA-RITE | Category: Swimming Pool Heater | Size: 1.92 MB. Table of Contents.$14.99 $43.60 Free Shipping Hassle Free Return Quantity: Add to cart Description A stack flue sensor, located on the exhaust elbow of a pool heater, prevents the flue gas output from exceeding 500°F. When this fails, your system will show error codes E05 or E06 to indicate that the stack flue sensor must be replaced. This control board kit is designed to use with Pentair MasterTemp NA and LP Series pool and spa heater electrical systems. Also fits Pentair Sta-Rite Max-E-Therm NA and LP Series pool and spa heater electrical systems. Measures 6-inch length by 6-inch height by 6-inch width. Do not attempt to adjust the gas input by adjusting the regulator setting.Pentair ETi 400 ASME High Efficiency Pool & Spa Heater Residential Model. Pentair ETi 250 ASME High Efficiency Pool & Spa Heater ... Max-E-Therm. The Max-E-Therm features sleek, contemporary styling that offers pool owners an easy choice over the traditional style. The lightweight, compact design is ideal for retro-fit installation. is michelle rotella pregnant Pentair Mu understanding is that this code signals that the stack flue programming is incorrect, what is your thoughts and if this is correct how do you program the Ad0 or Ad1 coded? Ask the Pool Guy Changed status to publish April 29, 20207 subscribers. Subscribe. No views 1 minute ago. Pentair Sta-Rite SR400NA Pool Spa Heater Max-E Therm 400K BTU Natural Gas Heater Igniter repair https://www.poolzoom.com/igniter-w-ga... Try ... lancaster missed connections Posted May 31, 2013. I've got a Sta-Rite Max-E-Therm 400 and it won't start. When I power it up, the display shows 888 with the "Pool On" light green, then the "Pool On" light goes off and and the display changes to 128, then the display reads r=8, then E06 and the "Service Heater" lights up red. On the back of the panel, all the LEDs flash ...Once you have established you are getting power through the transformer (24 volts) or from the Pilot Generator, aka thermopile, (400-600 mv), then we “follow” the power with our multi-meter, looking for a Voltage Drop at any one of the components in the heater. “The Problem Lies Where the Power Dies”Sep 25, 2017. #1. Hi. I have a sta rite sa 400na pool heater that just started acting up. the blower and burner come on for a little while but go off. when this happens, the service heater light comes on and burner goes out. after a short period of time the light goes out and the heater fires back up increases temp 1-2 degrees and then light ...starite. own a Sta Rite Max E Terrm 400 H Model # C3030and cannot get combustion as it just blows air. Took picture of board and it's showing showing red light onHLS andLED11. Green light is showing o …Check for water in the combustion chamber by removing a bottom bolt on the manifold. If water comes out, the combustion chamber has water in it, which is usually due to a leak in the heat exchanger. View attachment …we have a Sta Rite Max-E-Therm 400. The heater comes on, runs for a minute and turns off. Red service heater light comes on. after 30seconds heater ignites again runs for a minute or so. turns off again. on the back of the control panel the diode for HLS comes on i replaced the sensor, the thermistor and the thermal regulator. next i … tv listings columbus ohio over the airutrgv ucentral number we just installed a new gas line with 7.5WC to sta-rite max-e-therm 400 pool heater. the start up for flame is normal, when flame kicks on it blows a torch like flame out of the exhaust. any ideas wha … read moreChlorine. Salt Water Generator. SWG Type. Pentair Intellichlor IC-40. Jan 16, 2014. #3. Re: Pentair MasterTemp 400 heaters shutting down with no err. The Master Temp doesn't always show codes for failures. There are LEDs on the back of the circuit board (behind the thermostats) that light up for some of the errors. currency serial number lookup Code Requirements 7 Consumer Information and Safety Information 7 Safety Information 8 General Specifications 9 Section 2. Installation 10 Heater Description 10 Sequence of Operation/Putting the Heater into Service 10 Specifications 11 Plumbing ConnectionsFunmit 42002-0024S Stack Flue Sensor Replacement for Pentair Sta-Rite MasterTemp Max-E-Therm Pool and Spa Heater Electrical System SR200 SR333 SR400. 4.6 out of 5 stars 225. 600+ bought in past month ... Romalon 42002-0024S Flue Stack Sensor Replacement for 400 Pool and Spa Heater Electrical Systems (2 Pack) 4.7 out of 5 stars …120. May 26, 2012. #1. Sta-Rite 333k NG heater won't fire the heater. Starts ok. Blower starts up. ~ 30 seconds- 1 min go by and it switches to service heater LED. None of the fault LED's on the bottom are lit. The Fenwal on … rockhounding arkansas map Jul 5, 2016 · Help!! SR400NA was running fine this summer. But I replaced a pump motor and wired it incorrectly (learned my lesson!) so I blew the main breaker which in turn blew all the breakers. Everything is working now except for the Max E Therm Heater. It hasn't fired since the breakers blew and has had a... Pentair Sta-Rite Sr400Hd Max-E-Therm Error Codes Ad0, Sf1, 888, 180, R4. Pool Heater; Sta-Rite; Ad0; Sf1; 888; 180; r4; SR400HDPentair Manifold Replacement. If you have a leak, break, crack, or broken manifold on your Pentair Mastertemp 125, 250, or 400, Pentair has provided instructions for how to replace this part in their Sta-Rite Max-E-Therm Heater Manifold Replacement Instructions pdf found at this link. This guide is taken from this manual to provide more clarity. lake namakagon fishing hot spotslowes advantage log in I have a stay right Max E therm 400 HD pool heater. When I first turn it on I get an error code saying r13. Then it turns on and runs correctly for about two minutes. At that point it …Sep 25, 2017. #1. Hi. I have a sta rite sa 400na pool heater that just started acting up. the blower and burner come on for a little while but go off. when this happens, the service heater light comes on and burner goes out. after a short period of time the light goes out and the heater fires back up increases temp 1-2 degrees and then light ...When I first turn on my pool heater (Sta Rite Max E Therm It goes off and the heater works as it should for about two minutes. Then the light comes on again and the … mickey spagnola age Here is what I have found so far: Note: The AFS unit has been replaced along with new tubes. 1) The "Service Heater" LED comes on right after the unit goes through it's initial electronic startup sequence along with the "AFS" LED on the underside of the control board. The Blower does spool up but there is no ignition.Help!! SR400NA was running fine this summer. But I replaced a pump motor and wired it incorrectly (learned my lesson!) so I blew the main breaker which in turn blew all the breakers. Everything is working now except for the Max E Therm Heater. It hasn't fired since the breakers blew and has had a...It's able to ignite the gas and heat the water for a few minutes before the heat led goes from solid to blinking and the burner turns off. The heater cycles for a couple times firing the burners and then turning off before the service heater led comes on. At this time the ignition status led is blinking 3 times in a row to indicate ignition ...Chlorine. Salt Water Generator. SWG Type. Pentair Intellichlor IC-40. Jan 16, 2014. #3. Re: Pentair MasterTemp 400 heaters shutting down with no err. The Master Temp doesn't always show codes for failures. There are LEDs on the back of the circuit board (behind the thermostats) that light up for some of the errors.Whether you are troubleshooting your heater for one specific problem, or simply looking to tune up your Pentair® MasterTemp® or Max-E-Therm®, this repair kit has what you need! This Kit Includes: (1) Stack Flue Sensor Replacement 42002-0024S. (1) Thermistor Replacement 42001-0053S. (1) Pressure Switch Replacement 3902.Thermistor or Temperature Sensor for Pentair Mastertemp, Waterco Turbotemp, Sta-Rite Max-E-Therm Gas Pool & Spa Heaters - 200 / 300 / 400 HD models. Commonly corrode, damaging the sensor and causing an E05 fault, or incorrect temperature. Number 7. in the Diagram. OEM sensors are chrome-plated brass. Aftermarket are fully Stainless Steel. 2. … osrs splitbark legs Jul 21, 2013 44,928 Northern NJ Pool Size 35000 Surface Plaster Chlorine Salt Water Generator SWG Type Pentair Intellichlor IC-60Item No. 604342 | Manufacturer SKU: 42002-0007S. Write a review. $579.99. Buy in monthly payments with Affirm on orders over $50. Learn more. 42002-0007S Replacement Control Board Kit for Pentair MasterTemp and Sta-Rite Max-E-Therm Pool Heaters for use with Natural and Propane Gas Heaters. More Details. buc ee's katy gas prices Home | Dominion Energy I have a 3 year old Sta-Rite heater (Max-E-Therm 400 BTU Natural Gas Heater). When I turn it on, the blower activates but the gas is not igniting; the front panel lights up the "Service Heater" item. When I turn the top over and look at the circuit board, it has LED 4 and LED 11 shining bright red. I would like to troubleshoot and fix this ...History maybe relevant: 1) blower began acting funny 4-5 years back - would not turn off, so I was managing this by turning it off using the breaker (did this for a couple winters) 2) Heater began to act erratically - would turn on randomly (I managed this by turning off the gas and leaving...the local and state codes before installing the Max-E-Therm. Its use will reduce service calls and chance of injury and will lengthen product life. History and experience has shown that most heater damage is caused by improper installation practices. IMPORTANT NOTICES...For the installer and operator of the Max-E-Therm pool and spa heater. thomas mikal ford grave the heater. All Max-E-Therm heaters are designed with a direct ignition device, HSI (hot-surface ignition), which eliminates the need for a standing pilot. The Max-E-Therm requires an external power source (120/240 VAC 60 Hz) to operate. SPECIAL INSTRUCTIONS TO OWNER: Retain this manual for future reference. This instruction manual providesMu understanding is that this code signals that the stack flue programming is incorrect, what is your thoughts and if this is correct how do you program the Ad0 or Ad1 coded? Ask the Pool Guy Changed status to publish April 29, 2020Jan 15, 2011 · I have a 3 year old Sta-Rite heater (Max-E-Therm 400 BTU Natural Gas Heater). When I turn it on, the blower activates but the gas is not igniting; the front panel lights up the "Service Heater" item. When I turn the top over and look at the circuit board, it has LED 4 and LED 11 shining bright red. I would like to troubleshoot and fix this ... MasterTemp 400: Natural Gas: 136: Available Through Dealer: 460737: MasterTemp 400: Propane: 136: Available Through Dealer: 460805: MasterTemp 400HD: Natural Gas: 136: ... MasterTemp and Max-E-Therm Smart Bypass Valve Kit: NA: 12: Available Through Dealer: Show less. Products beginning with EC- are exclusive to e-commerce sales.The temperature displayed is the water temperature. The SFS checks the exhaust gas temperature. To check the stack flue temperature, press and hold the "Pool On" button for about 5 to 10 seconds. If you remove the two halves of the heater cover, you can access the sfs. It's in the 90 of the exhaust flue.we just installed a new gas line with 7.5WC to sta-rite max-e-therm 400 pool heater. the start up for flame is normal, when flame kicks on it blows a torch like flame out of the exhaust. any ideas wha … read more pt to etdestiny 2 battleye query timeout we just installed a new gas line with 7.5WC to sta-rite max-e-therm 400 pool heater. the start up for flame is normal, when flame kicks on it blows a torch like flame out of the exhaust. any ideas wha … read more tcm schedule today #1 Hi there, My Sta-Rite Max-E-Therm 400 "service heater" lamp just came on. I have gone through the following trouble shooting steps: Cleaned pool filter catridges …- Auto (360p LQ) Laptop Troubleshooting and Repair Guide STA-RITE Max-E-Therm 400 Troubleshooting While the heater is not working at 90 percent, there is nothing wrong with the heater. Few reasons can term to the machine not working as, Someone got the pump basket clogged up Filter pressure got way too high The filters need to be back washed truereal tv schedule STA-RITE Max-E-Therm SR333LP Owner's Manual (40 pages) INSTALLATION, OPERATION & PARTS SR POOL AND SPA HEATER NATURAL GAS / LP GAS. Brand: STA-RITE | Category: Swimming Pool Heater | Size: 1.93 MB. Table of Contents.Sep 25, 2017. #1. Hi. I have a sta rite sa 400na pool heater that just started acting up. the blower and burner come on for a little while but go off. when this happens, the service heater light comes on and burner goes out. after a short period of time the light goes out and the heater fires back up increases temp 1-2 degrees and then light ...We have a Sta Rite Max-E-Therm 400. The heater comes on, runs for a minute and turns off. Red service heater light comes on. after 30seconds heater ignites again runs for a minute or so. turns off again. on the back of the control panel the diode for HLS comes on i replaced the sensor, the thermistor and the thermal regulator. next i disassembled the …940 satisfied customers. Pool temp at the heater display is reading 126 degrees and i. pool temp at the heater display is reading 126 degrees and i know the pools only 50 degrees heater wont fire because it think the pool temp is 126 … read more.we have a Sta Rite Max-E-Therm 400. The heater comes on, runs for a minute and turns off. Red service heater light comes on. after 30seconds heater ignites again runs for a minute or so. turns off again. on the back of the control panel the diode for HLS comes on i replaced the sensor, the thermistor and the thermal regulator. next i …I have a Stayrite Max-E-Therm 400 gas heater that was installed when I bought my house in March 2009. It's a fairly powerful heater and when working correctly, it'll quickly get the spa or pool to a nice temp. In recent months it's been doing something odd. valucraft battery I have a 3 year old Sta-Rite heater (Max-E-Therm 400 BTU Natural Gas Heater). When I turn it on, the blower activates but the gas is not igniting; the front panel lights up the "Service Heater" item. When I turn the top over and look at the circuit board, it has LED 4 and LED 11 shining bright red. I would like to troubleshoot and fix this ...May 31, 2013 · I've got a Sta-Rite Max-E-Therm 400 and it won't start. When I power it up, the display shows 888 with the "Pool On" light green, then the "Pool On" light goes off and and the display changes to 128, then the display reads r=8, then E06 and the "Service Heater" lights up red. Jan 22, 2020 · Once you have established you are getting power through the transformer (24 volts) or from the Pilot Generator, aka thermopile, (400-600 mv), then we “follow” the power with our multi-meter, looking for a Voltage Drop at any one of the components in the heater. “The Problem Lies Where the Power Dies” The "R3" is not a fault code, it's a revision of the board and is normal. The "Service Heater" is what needs concern. ... we just installed a new gas line with 7.5WC to sta-rite max-e-therm 400 pool heater. the start up for flame is normal, when flame kicks on it blows a torch like flame out of the exhaust. any ideas wha ...